Python demonstrates the working principle of an Active Harmonic Filter (AHF)

Understanding Active Harmonic Filter (AHF) Operation The Python code demonstrates the working principle of an Active Harmonic Filter (AHF), a device used to mitigate harmonic distortions in electrical systems. By analyzing current waveforms and frequency spectra, the code showcases the AHF’s ability to reduce harmonic content and improve power quality. Code Overview: The code reads …

Python demonstrates the working principle of an Active Harmonic Filter (AHF) Read More »

Demystifying THDi vs. TDD: Key Differences and Their Significance in Power Quality Analysis

Understanding THDi vs. TDD in Power Quality Analysis THDi (Total Harmonic Distortion) and TDD (Total Demand Distortion) are critical parameters used to evaluate harmonic distortion in electrical systems. While both metrics assess the presence of harmonics, they differ in their definitions, calculations, and significance. THDi (Total Harmonic Distortion) Definition: THDi measures the harmonic distortion in …

Demystifying THDi vs. TDD: Key Differences and Their Significance in Power Quality Analysis Read More »

Understanding IEEE 519 Harmonic Standard: A Comprehensive Guide

Understanding IEEE 519 Harmonic Standard: A Comprehensive Guide IEEE 519-2022, titled “Harmonic Control in Electric Power Systems,” is a vital standard that sets targets for electrical system design to mitigate harmonic distortion. Here’s what you need to know and where to start: Overview The IEEE 519-2014 standard defines voltage and current harmonic distortion standards in …

Understanding IEEE 519 Harmonic Standard: A Comprehensive Guide Read More »

Comprehensive Guide to Active harmonic filter(AHF) Calculation and Installation

Comprehensive Guide to AHF Calculation and Installation Active harmonic filter (AHF) play a crucial role in mitigating harmonic distortions and improving power quality in electrical systems. This comprehensive guide outlines the step-by-step process for AHF calculation, installation, parameter settings, and performance monitoring. Power Quality Audit: Prior to AHF installation, conduct a thorough power quality audit …

Comprehensive Guide to Active harmonic filter(AHF) Calculation and Installation Read More »

Selecting the Right CT for Active Harmonic Filter (AHF)

How to Select the Right CT for Active Harmonic Filter (AHF) Choosing the appropriate current transformer (CT) is crucial for the effective operation of active harmonic filters (AHFs) in harmonic mitigation applications. This article provides guidance on selecting the right CT for AHFs and highlights Enjoypowers’ versatile AHF modules with flexible CT installation options. Factors …

Selecting the Right CT for Active Harmonic Filter (AHF) Read More »

Calculating the Appropriate Size of an Active Harmonic Filter (AHF)

How to Calculate the Appropriate Size of an Active Harmonic Filter (AHF) Active harmonic filters (AHFs) are essential for mitigating harmonics and improving power quality in electrical systems. Choosing the right size AHF is crucial to ensure effective harmonic mitigation without oversizing or undersizing the equipment. This article outlines the steps involved in calculating the …

Calculating the Appropriate Size of an Active Harmonic Filter (AHF) Read More »

Comparative Analysis of Three-Level and Two-Level Active Harmonic Filter

Comparative Analysis of Three-Level and Two-Level Active Harmonic Filters In the realm of power quality improvement, active harmonic filters (AHFs) play a crucial role in mitigating harmonics and enhancing the efficiency of electrical systems. Two prominent topologies employed in AHFs are the three-level and two-level configurations. This article provides a comparative analysis of these two …

Comparative Analysis of Three-Level and Two-Level Active Harmonic Filter Read More »

Difference Between Active and Passive Harmonic Filter: Comprehensive Comparison

Understanding the Difference Between Active and Passive Harmonic Filter: A Comprehensive Comparison Harmonic distortion in power systems is a common issue that affects the quality and reliability of electrical energy. To mitigate this problem, both active and passive harmonic filters are employed. Understanding the differences between these two types of filters is crucial for selecting …

Difference Between Active and Passive Harmonic Filter: Comprehensive Comparison Read More »

Good News | Enjoy Technology Won the “2023 Best Supplier Award for Energy Storage Small and Medium Power Bidirectional Converters”

From August 28th to September 1st, the 2nd China International Energy Storage Exhibition and 10th China International Optical Storage Conference, organized by the EESA Energy Storage Leaders Alliance, went smoothly in Suzhou Convene. Enjoy Technology won the “2023 Best Supplier of Energy Storage Small and Medium Power Bidirectional Converters Award” for its outstanding energy storage …

Good News | Enjoy Technology Won the “2023 Best Supplier Award for Energy Storage Small and Medium Power Bidirectional Converters” Read More »

Good News|Enjoy Technology has won the Best PCS Supply Award in China’s Energy Storage Industry!

On May 24th, the 13th China International Energy Storage Conference 2023 was grandly held at the InterContinental Hotel in Hangzhou. The theme of the conference was “promoting the construction of a new energy system and promoting the high-quality development of the energy storage industry”, focusing on the safe and sustainable development of new energy storage. …

Good News|Enjoy Technology has won the Best PCS Supply Award in China’s Energy Storage Industry! Read More »

Scroll to Top